LADP-16 Apparatus for Determining Planck’s Constant – Advanced Model

Demonstration of  the photoelectric effect, measure the characteristic curve of a photoelectric tube, verify the existence of "red limit" frequency, and calculate Planck’s constant according to the Einstein’s equation of photoelectric effect   Specifications  
Description Specifications
Wavelength of filters 365 nm, 405 nm, 436 nm, 546 nm, 577 nm
Size of apertures 2 mm, 4 mm, 8 mm, 10 mm, 12 mm
Light source 50 W Mercury lamp
Photocell Wavelength range: 340 ~ 700 nm
Cathode sensitivity: ≥1 µA (-2 V ≤ UKA ≤ 0 V)
Anode dark current: ≤5×10-12 A (-2 V ≤ UKA ≤ 0 V)
Current range 10-7 ~ 10-13 A, 3-1/2 digit display
Voltage range I: -2 ~ +2 V; II: -2 ~ +20 V, 3-1/2 digit display, stability ≤0.1 %
Zero drift < ±0.2% of full scale (for scale 10-13 A) within 30 minutes after warm-up
Measurement method Zero current method and compensation method
Measurement error 3%
  Parts List  
Description Qty
Main Unit 1
Electric Control Unit 1
Special BNC Cable 2
USB Cable 1
Software CD 1
Power Cord 1
Instructional Manual 1